• West 1 Building 4th Floor, Corner of Wambugu Grove | sales@esteckenya.com
        • Tel:+254-20-6537709

Category: OIL & GAS INDUSTRY SOLUTIONS

SVM 4001: Fastest viscosity index (VI) determination compliant to ASTM D2270, from the lowest sample volume.b

ANTON PAAR.
SVM 4001, SVM 3001 & SVM 3001 COLD PROPERTIES.
SVM 4001: Fastest viscosity index (VI) determination compliant to ASTM D2270, from the lowest sample volume. Convenient viscosity-temperature extrapolation according to ASTM D341.
Innovative double-cell design for simultaneous measurement of kinematic viscosity and density at any two temperatures between +15 °C and +100 °C for example:
·        40 °C and 100 °C for viscosity index of base oils and lube blends
·        50 °C and 100 °C for viscosity of heavy fuel oils
·        15 °C for density and 40 °C for viscosity of fuel oils

APPLICATION: 

Base and Lube Oils | Viscosity Index of Base and Lube Oils with SVM 4001
SVM 3001: is more than a viscometer, it gives you more parameters than any other kinematic viscometer on the market. A single measurement on a small sample volume yields kinematic viscosity, density, dynamic viscosity, viscosity index and more. Kinematic viscosity fully compliant with ASTM D7042 & Density measurement according to ASTM D4052 and ISO 12185:

Characteristics.
Multi parameter measurement from a single syringe
Minimum sample volume of 1.5 mL.
Wide temperature ranges from -60 °C to +135 °C
Wide viscosity ranges from 0.2 to 30 000 mm2/s
APPLICATION 2:

Jet fuel, used oil, Lube oils and Diesel with SVM 3001

SVM 4001, SVM 3001 & SVM 3001 COLD PROPERTIES.

ANTON PAAR

SVM 4001, SVM 3001 & SVM 3001 COLD PROPERTIES.
SVM 4001: Fastest viscosity index (VI) determination compliant to ASTM D2270, from the lowest sample volume. Convenient viscosity-temperature extrapolation according to ASTM D341.
Innovative double-cell design for simultaneous measurement of kinematic viscosity and density at any two temperatures between +15 °C and +100 °C for example:
·        40 °C and 100 °C for viscosity index of base oils and lube blends
·        50 °C and 100 °C for viscosity of heavy fuel oils
·        15 °C for density and 40 °C for viscosity of fuel oils

APPLICATION: 

  • Base and Lube Oils | Viscosity Index of Base and Lube Oils with SVM 4001
    SVM 3001: is more than a viscometer, it gives you more parameters than any other kinematic viscometer on the market.
  • A single measurement on a small sample volume yields kinematic viscosity, density, dynamic viscosity, viscosity index and more. Kinematic viscosity fully compliant with ASTM D7042 & Density measurement according to ASTM D4052 and ISO 12185.
  • Multi parameter measurement from a single syringe
  • Minimum sample volume of 1.5 mL.
  • Wide temperature ranges from -60 °C to +135 °C.
  • Wide viscosity ranges from 0.2 to 30 000 mm2/s

APPLICATION:

Jet fuel, used oil, Lube oils and Diesel with SVM 3001.

INFLUENCE OF OXIDATION STABILITY ON QUALITY, EFFECTIVENESS, AND SHELF-LIFE OF A PRODUCT

In many cases, the quality, effectiveness, and shelf-life of a product strongly depend on its oxidation stability. Therefore, it is absolutely crucial to know the oxidative behavior as it can directly correlate to a negative consumer’s perception. In order to guarantee that all properties of a product are maintained until used, we offer a powerful tool with the RapidOxy 100.

One of the major benefits is its applicability with all kinds of products, like fluid, semi-solid, and solid samples which can be measured without any prior sample preparation. With the RapidOxy 100, Anton Paar clearly provides a simple and in many aspects time as well as a cost-saving way to determine, investigate, and if necessary also improve the oxidative behavior of various products.

Kindly contact us to learn how the RapidOxy 100 combines fully automatic accelerated aging with monitoring the oxygen consumption to enable:

  • Screening of antioxidants, ingredients, processes, etc.
  • Monitoring quality and storage conditions over time
  • Estimating shelf-life of raw materials, components, and of the finished product

We are always at your service.

REFINERY GAS ANALYZER WITH VOLATILE SULFUR SPECIATION- AN INNOVATIVE AND EFFICIENT SOLUTION

Determining the composition of refinery gas and measurement of trace sulfur content is very crucial in Hydrocarbon Processing Industry gas chromatography applications. Trace amounts of volatile sulfurs present in gas streams can poison the catalyst used in processes, which can cost millions of dollars.

Shimadzu recently launched the highly sensitive Nexis SCD-2030 that is used in combination with the existing High-Speed Refinery Gas Analyzer for speciation and quantification of trace sulfur components. This complete system, which has four detectors operating simultaneously, is a very accurate, robust, and efficient solution complying with ASTM D7833, UOP 539, and ASTM D5504 methods.

Kindly contact us to know more about this state-of-the-art analyzer and new industry-standard SCD detector and their unique synergy that maximizes operational efficiency and minimizes total cost.